① Latching Relay | |
② Part Number | |
③ Coil Voltage | |
④ D= Double Coil; S= Single Coil | |
⑤ 60=60A |
Insulation resistance | 1000MΩ (500VDC) | |
DielectricStrength | BetweenCoil&Contacts | 4000VAC 1min |
Between Open Contacts | 1500VAC 1min | |
Operate Time | 15msec. Max. | |
Release Time | 15msec. Max. | |
Shockresistance | Functional | 100m/S 2 (10g) |
Destructive | 1000m/S 2 (100g) | |
Vibration resistance | 10~55Hz 1.5mm | |
Humidity | 98%RH ,40℃ | |
Ambient temperature | -40~70℃ | |
Temination | Fast connection | |
Unit weight | 42g | |
Constrution | Dust protected |
Contact form | 1B |
Contact material | AgSnO2 |
Contact resistance | Max: 1.5mΩ |
Contact Rating | 60A 250VAC |
Max. Switching Power | 15000VA |
Mechanical life | 5×106 |
Electrical life | 1×104 |
Coil power | Single coil: 1.0W Double coil: 2.0W |
(VDC) |
(VDC) |
(ms) |
(Ω) |
Rated Voltage |
Pick-up voltage |
Pulse Duration |
Coil Resistance |
Single coil | |||
9 |
6.75 |
50 |
80±10% |
12 |
9 |
50 |
144±10% |
24 |
18 |
50 |
576±10% |
48 |
36 |
50 |
2304±10% |
Double coil | |||
9 |
6.75 |
50 |
2×40±10% |
12 |
9 |
50 |
2×72±10% |
24 |
18 |
50 |
2×288±10% |
48 |
36 |
50 |
2×1152±10% |
Note: Special ordering for other coil voltage.
Typical Application
Prepayment Energy Meter; AMR System;
Compound Switch; Automatic Control System.
Please contact us at info@advancedamorphous.com for your enquiries. Our engineering team can customized the product to suit your requirements.