① Latching Relay |
| ② Part Number | |
| ③ Coil Voltage | |
| ④ D= Double Coil; S= Single Coil | |
| ⑤ 60=60A |
| Insulation resistance | 1000MΩ (500VDC) | |
| DielectricStrength | BetweenCoil&Contacts | 4000VAC 1min |
| Between Open Contacts | 1500VAC 1min | |
| Operate Time | 15msec. Max. | |
| Release Time | 15msec. Max. | |
| Shockresistance | Functional | 100m/S 2 (10g) |
| Destructive | 1000m/S 2 (100g) | |
| Vibration resistance | 10~55Hz 1.5mm | |
| Humidity | 98%RH ,40℃ | |
| Ambient temperature | -40~70℃ | |
| Temination | Fast connection | |
| Unit weight | 42g | |
| Constrution | Dust protected | |
| Contact form | 1B |
| Contact material | AgSnO2 |
| Contact resistance | Max: 1.5mΩ |
| Contact Rating | 60A 250VAC |
| Max. Switching Power | 15000VA |
| Mechanical life | 5×106 |
| Electrical life | 1×104 |
| Coil power | Single coil: 1.0W Double coil: 2.0W |
| (VDC) |
(VDC) |
(ms) |
(Ω) |
| Rated Voltage |
Pick-up voltage |
Pulse Duration |
Coil Resistance |
| Single coil | |||
|
9 |
6.75 |
50 |
80±10% |
|
12 |
9 |
50 |
144±10% |
|
24 |
18 |
50 |
576±10% |
|
48 |
36 |
50 |
2304±10% |
| Double coil | |||
|
9 |
6.75 |
50 |
2×40±10% |
|
12 |
9 |
50 |
2×72±10% |
|
24 |
18 |
50 |
2×288±10% |
|
48 |
36 |
50 |
2×1152±10% |
Note: Special ordering for other coil voltage.
Typical Application
Prepayment Energy Meter; AMR System;
Compound Switch; Automatic Control System.

Please contact us at info@advancedamorphous.com for your enquiries. Our engineering team can customized the product to suit your requirements.